VITECTOR
Incorrect email or password. Please try again.

Pedestrian Door Switch (ENS)

ens_1

ENTRYSENSE

Wicket doors in panels of power operated doors have to be locked safely in their closing position prior to any operation of the gate. This is applicable to fully automated gates as well as to gates in deadman-mode. A safe contact has to prevent the gate from moving while the wicket door is not fully closed.

ENTRYSENSE is available in three versions to work with different door control units.

ENS-S 6800

  • Safe Door Contact, EN 12453: 2017
  • Safety Category 2, EN 13849-1: 2016
  • Internal Resistor 2k, Suitable for Cross-Fault Monitoring
  • Non-Tactile Sensor – No Wearing
  • Adjustable Switching Point
  • Cable Length 5 m

ENS-S 6800 Datasheet

ENS-S 6804

  • Safe Door Contact, EN 12453: 2017
  • Safety Category 2, EN 13849-1: 2016
  • Internal Resistor 2k, Suitable for Cross-Fault Monitoring
  • Non-Tactile Sensor – No Wearing
  • Adjustable Switching Point
  • Cable Length 20 m

ENS-S 6804 Datasheet

ENS-S 8200

  • Safe Door Contact, EN 12453: 2017
  • Safety Category 2, EN 13849-1: 2016
  • Established 8k2 Interface
  • Non-Tactile Sensor – No Wearing
  • Adjustable Switching Point
  • Cable Length 5 m

ENS-S 8200 Datasheet

ENS-S 1000

  • Fused, redundant NCC with Diode Interface
  • Non-Tactile Sensor – No Wearing
  • Adjustable Switching Point
  • Cable Length: 5m

ENS-S 1000 Datasheet